SIL. ALM#1:NO (silent alarm)
When this option is selected, alarm conditions will not be annunciated audibly, but will be
reported to the central station.
NOTE Holdup zones must be selected as SIL. ARM.
REP.DLY#1:NO
Select this option to create a delay between the time that an alarm condition is sensed by the
zone and the time that the system reports the alarm. The delay time is programmed in TIMERS
(Menu 13).
BELL DLY#1:NO
If this option is selected, there will be no bell output unless the dialer fails.
NO SHUTDOWN#1:NO
If this option is selected, the bell will not shut down until the panel is disarmed.
ZONE:#2
Select the next zone to program. The options will repeat for all 80 zones.
5.10 Accounts (Menu 9)
ACCOUNT:#1(1-4)
Select which account (1-4) you wish to reprogram.
PHONE NUMBER#1:
Enter Phone #1, up to 16-digits. Enter “A” (01) for a pause, “D” (04) for a second dial tone.
Press 6 before each digit of the phone number. (See Section 5.8 of this manual for an exam-
ple.)
ACCT #1:000000
Enter the digits for the account number (6-digits maximum).
REP ALRM#1:YES
Select this option if you want alarms to be reported to Phone #1.
REP TRBL#1:YES
Select this option if you want trouble conditions to be reported to Phone #1.
REP BYPS#1:NO
Select this option if you want bypass (shunted) to be reported to Phone #1.
REP RSTR#1:NO
Select this option if you want restorals to be reported to Phone #1. Restores will report only to
the same numbers that the alarm or bypass reported to.
REP OPRST#1:NO (report open reset, Phone #1)
Select this option if you want the system to report to Phone #1 when the system is disarmed
from an alarm condition. If you will select the next option (REP OP/CL#1) for Phone #1, you
must also select REP OPRST#1.