Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
5
Plug the Model 4181 into a 120 VAC, 60 Hz wall outlet to the panel. Use a 4-wire modular
phone cable (P/N 130071, supplied) to connect the 4181 to the modular jack (P5) on the 4734
as shown in Figure 2. The maximum length of the cable is 20 feet. The 4181 is optically iso-
lated from the powerline.
NOTE The modular connectors on both the 4734 and the 4181 must NOT be connected to a phone
line or anything other than each other. The X-10 modules may be distributed throughout the
building.
To install the X-10 modules, plug them into outlets close to the appliances you want them to
control.
Figure 2: Model 4181 Connections
M odel 4720
Model
4734/4734-2
8457G20A.DSF
Do not connect P5 to a phone line.
P5
The 4181 LED is normally on when power
is applied. The LED flashes during transmission.
Modular Cable
Model 4181
(PL513)
Power Line
Interface