Regency
®
Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
16
START#0:00:00
Using military time, key in the beginning time for the window.
END#0:00:00
Key in the ending time for the window.
NOTE Time windows may cross midnight.
DAYS#0:SMTWTFSH
Select the days on which the window will be active by toggling the digits 0 through 7 on and
off.
EXAMPLE 1: If you want Time Window #0, which has been programmed to last from
7:00 AM to 8:30 AM, to be in effect on weekdays, select:
-MTWTF-
by toggling keys 1 through 5 ON and keys 0, 6 and 7 OFF.
EXAMPLE 2: If you want Time Window #3, which has been programmed to last from
8:00 AM to 9:00 AM, to be in effect on Sundays and holidays, then when you program
DAYS#3:SMTWTFSH, select:
S------H
by toggling keys 0 and 7 ON and keys 1 through 6 OFF.
NUMBER:#1
Select the next time window to program. Continue programming the options for up to 32 time
windows.
The easiest way to disable a time window is to go to the DAYS option (TIME WINDOWS,
Menu 0) and deselect all days by pressing CLR TEST.
5.2 Codes/Cards (Menu 1)
Secret codes or cards and profile assignments can be programmed by the end user.
NOTE 1. The programming steps for Code 0 (installer’s code) and Code 1 (main user’s code) profiles
have no effect because they are fixed. Code 0 can always activate all features and can program
all options. Code 1 can activate all control functions (arming, disarming, bypassing, etc.), and
can program all user-programmable options.
2. Built-in programmer Menu 1 (Codes/Cards) is the same as the menu accessed with 7 TEST.
BULK LOAD:NO
Select YES if you will be loading cards which will all be using the same profile. Select NO if
you will be manually entering secret codes or if you are entering codes that will each have dif-
ferent profiles.
NUMBER:#2
Select the access code for which you want to program the options. Enter the identifying num-
ber
—Code 2, Code 3, etc.—not the secret code. The code range is 0-999.
PROFILE#2:0
Select one of the 16 user profiles for this access code. If Bulk Load was selected, this profile
will be used for all codes entered.